GEOS-Chem horizontal grids

From Geos-chem
Revision as of 22:53, 10 November 2016 by Bmy (Talk | contribs) (GMAO 2x25 grid)

Jump to: navigation, search

Page is under construction.jpg

GCAP 4x5 grid

Grid gcap4x5.png

GCAP 4° x 5° longitude edges:

-182.500 -177.500 -172.500 -167.500 -162.500 -157.500 -152.500 -147.500 -142.500 -137.500 -132.500 -127.500 -122.500 -117.500   
-112.500 -107.500 -102.500  -97.500  -92.500  -87.500  -82.500  -77.500  -72.500  -67.500  -62.500  -57.500  -52.500  -47.500  
 -42.500  -37.500  -32.500  -27.500  -22.500  -17.500  -12.500   -7.500   -2.500    2.500    7.500   12.500   17.500   22.500   
  27.500   32.500   37.500   42.500   47.500   52.500   57.500   62.500   67.500   72.500   77.500   82.500   87.500   92.500
  97.500  102.500  107.500  112.500  117.500  122.500  127.500  132.500  137.500  142.500  147.500  152.500  157.500  162.500
 167.500  172.500  177.500

GCAP 4° x 5° longitude centers:

-180.000 -175.000 -170.000 -165.000 -160.000 -155.000 -150.000 -145.000 -140.000 -135.000 -130.000 -125.000 -120.000 -115.000 
-110.000 -105.000 -100.000  -95.000  -90.000  -85.000  -80.000  -75.000  -70.000  -65.000  -60.000  -55.000  -50.000  -45.000
 -40.000  -35.000  -30.000  -25.000  -20.000  -15.000  -10.000   -5.000    0.000    5.000   10.000   15.000   20.000   25.000 
  30.000   35.000   40.000   45.000   50.000   55.000   60.000   65.000   70.000   75.000   80.000   85.000   90.000   95.000
 100.000  105.000  110.000  115.000  120.000  125.000  130.000  135.000  140.000  145.000  150.000  155.000  160.000  165.000
 170.000  175.000

GCAP 4° x 5° latitude edges:

 -90.000  -86.000  -82.000  -78.000  -74.000  -70.000  -66.000  -62.000  -58.000  -54.000  -50.000  -46.000  -42.000  -38.000
 -34.000  -30.000  -26.000  -22.000  -18.000  -14.000  -10.000   -6.000   -2.000    2.000    6.000   10.000   14.000   18.000
  22.000   26.000   30.000   34.000   38.000   42.000   46.000   50.000   54.000   58.000   62.000   66.000   70.000   74.000
  78.000   82.000   86.000   90.000

GCAP 4° x 5° latitude centers:

 -88.000  -84.000  -80.000  -76.000  -72.000  -68.000  -64.000  -60.000  -56.000  -52.000  -48.000  -44.000  -40.000  -36.000
 -32.000  -28.000  -24.000  -20.000  -16.000  -12.000   -8.000   -4.000    0.000    4.000    8.000   12.000   16.000   20.000
  24.000   28.000   32.000   36.000   40.000   44.000   48.000   52.000   56.000   60.000   64.000   68.000   72.000   76.000
  80.000   84.000   88.000

GMAO 4x5 grid

Grid gmao4x5.png

GMAO 4° x 5° longitude edges:

-182.500 -177.500 -172.500 -167.500 -162.500 -157.500 -152.500 -147.500 -142.500 -137.500 -132.500 -127.500 -122.500 -117.500 
-112.500 -107.500 -102.500  -97.500  -92.500  -87.500  -82.500  -77.500  -72.500  -67.500  -62.500  -57.500  -52.500  -47.500 
 -42.500  -37.500  -32.500  -27.500  -22.500  -17.500  -12.500   -7.500   -2.500    2.500    7.500   12.500   17.500   22.500
  27.500   32.500   37.500   42.500   47.500   52.500   57.500   62.500   67.500   72.500   77.500   82.500   87.500   92.500
  97.500  102.500  107.500  112.500  117.500  122.500  127.500  132.500  137.500  142.500  147.500  152.500  157.500  162.500
 167.500  172.500  177.500

GMAO 4° x 5° longitude centers:

-180.000 -175.000 -170.000 -165.000 -160.000 -155.000 -150.000 -145.000 -140.000 -135.000 -130.000 -125.000 -120.000 -115.000
-110.000 -105.000 -100.000  -95.000  -90.000  -85.000  -80.000  -75.000  -70.000  -65.000  -60.000  -55.000  -50.000  -45.000
 -40.000  -35.000  -30.000  -25.000  -20.000  -15.000  -10.000   -5.000    0.000    5.000   10.000   15.000   20.000   25.000
  30.000   35.000   40.000   45.000   50.000   55.000   60.000   65.000   70.000   75.000   80.000   85.000   90.000   95.000
 100.000  105.000  110.000  115.000  120.000  125.000  130.000  135.000  140.000  145.000  150.000  155.000  160.000  165.000
 170.000  175.000

GMAO 4° x 5° latitude edges:

 -90.000  -88.000  -84.000  -80.000  -76.000  -72.000  -68.000  -64.000  -60.000  -56.000  -52.000  -48.000  -44.000  -40.000
 -36.000  -32.000  -28.000  -24.000  -20.000  -16.000  -12.000   -8.000   -4.000    0.000    4.000    8.000   12.000   16.000
  20.000   24.000   28.000   32.000   36.000   40.000   44.000   48.000   52.000   56.000   60.000   64.000   68.000   72.000
  76.000   80.000   84.000   88.000   90.000

GMAO 4° x 5° latitude centers:

 -89.000  -86.000  -82.000  -78.000  -74.000  -70.000  -66.000  -62.000  -58.000  -54.000  -50.000  -46.000  -42.000  -38.000
 -34.000  -30.000  -26.000  -22.000  -18.000  -14.000  -10.000   -6.000   -2.000    2.000    6.000   10.000   14.000   18.000
  22.000   26.000   30.000   34.000   38.000   42.000   46.000   50.000   54.000   58.000   62.000   66.000   70.000   74.000
  78.000   82.000   86.000   89.000

GMAO 2x25 grid

Grid gmao2x25.png

GMAO 2° x 2.5° longitude edges:

-181.250 -178.750 -176.250 -173.750 -171.250 -168.750 -166.250 -163.750 -161.250 -158.750 -156.250 -153.750 -151.250 -148.750
-146.250 -143.750 -141.250 -138.750 -136.250 -133.750 -131.250 -128.750 -126.250 -123.750 -121.250 -118.750 -116.250 -113.750
-111.250 -108.750 -106.250 -103.750 -101.250  -98.750  -96.250  -93.750  -91.250  -88.750  -86.250  -83.750  -81.250  -78.750
 -76.250  -73.750  -71.250  -68.750  -66.250  -63.750  -61.250  -58.750  -56.250  -53.750  -51.250  -48.750  -46.250  -43.750
 -41.250  -38.750  -36.250  -33.750  -31.250  -28.750  -26.250  -23.750  -21.250  -18.750  -16.250  -13.750  -11.250   -8.750
  -6.250   -3.750   -1.250    1.250    3.750    6.250    8.750   11.250   13.750   16.250   18.750   21.250   23.750   26.250
  28.750   31.250   33.750   36.250   38.750   41.250   43.750   46.250   48.750   51.250   53.750   56.250   58.750   61.250
  63.750   66.250   68.750   71.250   73.750   76.250   78.750   81.250   83.750   86.250   88.750   91.250   93.750   96.250
  98.750  101.250  103.750  106.250  108.750  111.250  113.750  116.250  118.750  121.250  123.750  126.250  128.750  131.250
 133.750  136.250  138.750  141.250  143.750  146.250  148.750  151.250  153.750  156.250  158.750  161.250  163.750  166.250
 168.750  171.250  173.750  176.250  178.750

GMAO 2° x 2.5° longitude centers:

-180.000 -177.500 -175.000 -172.500 -170.000 -167.500 -165.000 -162.500 -160.000 -157.500 -155.000 -152.500 -150.000 -147.500
-145.000 -142.500 -140.000 -137.500 -135.000 -132.500 -130.000 -127.500 -125.000 -122.500 -120.000 -117.500 -115.000 -112.500
-110.000 -107.500 -105.000 -102.500 -100.000  -97.500  -95.000  -92.500  -90.000  -87.500  -85.000  -82.500  -80.000  -77.500
 -75.000  -72.500  -70.000  -67.500  -65.000  -62.500  -60.000  -57.500  -55.000  -52.500  -50.000  -47.500  -45.000  -42.500
 -40.000  -37.500  -35.000  -32.500  -30.000  -27.500  -25.000  -22.500  -20.000  -17.500  -15.000  -12.500  -10.000   -7.500
  -5.000   -2.500    0.000    2.500    5.000    7.500   10.000   12.500   15.000   17.500   20.000   22.500   25.000   27.500
  30.000   32.500   35.000   37.500   40.000   42.500   45.000   47.500   50.000   52.500   55.000   57.500   60.000   62.500
  65.000   67.500   70.000   72.500   75.000   77.500   80.000   82.500   85.000   87.500   90.000   92.500   95.000   97.500
 100.000  102.500  105.000  107.500  110.000  112.500  115.000  117.500  120.000  122.500  125.000  127.500  130.000  132.500
 135.000  137.500  140.000  142.500  145.000  147.500  150.000  152.500  155.000  157.500  160.000  162.500  165.000  167.500
 170.000  172.500  175.000  177.500

GMAO 2° x 2.5° latitude edges:

 -90.000  -89.000  -87.000  -85.000  -83.000  -81.000  -79.000  -77.000  -75.000  -73.000  -71.000  -69.000  -67.000  -65.000
 -63.000  -61.000  -59.000  -57.000  -55.000  -53.000  -51.000  -49.000  -47.000  -45.000  -43.000  -41.000  -39.000  -37.000
 -35.000  -33.000  -31.000  -29.000  -27.000  -25.000  -23.000  -21.000  -19.000  -17.000  -15.000  -13.000  -11.000   -9.000
  -7.000   -5.000   -3.000   -1.000    1.000    3.000    5.000    7.000    9.000   11.000   13.000   15.000   17.000   19.000
  21.000   23.000   25.000   27.000   29.000   31.000   33.000   35.000   37.000   39.000   41.000   43.000   45.000   47.000
  49.000   51.000   53.000   55.000   57.000   59.000   61.000   63.000   65.000   67.000   69.000   71.000   73.000   75.000
  77.000   79.000   81.000   83.000   85.000   87.000   89.000   90.000

GMAO 2° x 2.5° latitude centers:

 -89.500  -88.000  -86.000  -84.000  -82.000  -80.000  -78.000  -76.000  -74.000  -72.000  -70.000  -68.000  -66.000  -64.000
 -62.000  -60.000  -58.000  -56.000  -54.000  -52.000  -50.000  -48.000  -46.000  -44.000  -42.000  -40.000  -38.000  -36.000
 -34.000  -32.000  -30.000  -28.000  -26.000  -24.000  -22.000  -20.000  -18.000  -16.000  -14.000  -12.000  -10.000   -8.000
  -6.000   -4.000   -2.000    0.000    2.000    4.000    6.000    8.000   10.000   12.000   14.000   16.000   18.000   20.000
  22.000   24.000   26.000   28.000   30.000   32.000   34.000   36.000   38.000   40.000   42.000   44.000   46.000   48.000
  50.000   52.000   54.000   56.000   58.000   60.000   62.000   64.000   66.000   68.000   70.000   72.000   74.000   76.000
  78.000   80.000   82.000   84.000   86.000   88.000   89.500

GMAO 1 x 1.25 grid

Grid gmao1x125.png

GMAO 1 x 1 grid

Grid gmao1x1.png

Generic 1 x 1 grid

Grid generic1x1.png

GMAO 0.5 x 0.666 grid

Grid gmao05x0666.png

0.5 x 0.666 CH nested grid

0.5 x 0.666 EU nested grid

0.5 x 0.666 NA nested grid

GMAO 0.5 x 0.625 grid

0.5 x 0.625 AS nested grid

0.5 x 0.625 EU nested grid

0.5 x 0.625 NA nested grid

GMAO 0.25 x 0.3125 grid

Grid gmao025x03125.png

0.25 x 0.3125 CH nested grid

0.25 x 0.3125 EU nested grid

0.25 x 0.3125 NA nested grid